12 Months from Installation OR 18 Months from Delivery.
25 NB to 1400mm Available
230 V AC / 24 V DC Volt (v)
Full Bore Type Electromagnetic Flow Meter
100 Deg C Celsius (oC)
MS, SS.04, SS.316
Electromagnetic Flow Meters Trade Information
Paypal Cash Against Delivery (CAD) Cash on Delivery (COD) Cash Advance (CA) Cash in Advance (CID) Cheque Days after Acceptance (DA) Delivery Point (DP) Letter of Credit at Sight (Sight L/C) Telegraphic Transfer (T/T) Western Union Letter of Credit (L/C)
200 Piece Per Month
4 Days
Yes
If order is confirmed we will reimburse the sample cost
Asia Central America North America South America Western Europe Middle East Africa
Himachal Pradesh Jammu and Kashmir Madhya Pradesh Maharashtra Nagaland Rajasthan Sikkim Tamil Nadu Telangana Tripura Pondicherry Uttar Pradesh Uttarakhand West Bengal All India South India Central India West India North India East India Gujarat Karnataka Kerala Lakshadweep Mizoram Meghalaya Manipur Andhra Pradesh Bihar Chandigarh Daman and Diu Goa Jharkhand Odisha Punjab Assam Delhi Dadra and Nagar Haveli Andaman and Nicobar Islands Arunachal Pradesh Chhattisgarh Haryana
Product Description
Product Description:
The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service.
Measurement :
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.
Working Principle:
This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
Applications:
Scientific laboratory
Research centres
Chemical industries
Specifications:
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm): 15 to 1400mm
Material of Construction: MS, SS 304, SS 316 & SS 316L
Electrode Material: SS 316, SS 316L, Hastelloy 'c, & Tantalum
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Flow Tube Material: SS 316
End Connection: Flange/Wafer
Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum